TCX® (I) 150/250 (300) V

Products

TCX (I) 150/250V 2P0.75

Nexans ref. 10170061 - Country ref. 01101293

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 10.0 mm
  • Maximum outer diameter: 12.0 mm
  • Approximate weight: 153 kg/km

 

TCX (I) 150/250V 4P0.75

Nexans ref. 10170094 - Country ref. 01101294

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 216 kg/km

 

TCX (I) 150/250V 7P0.75

Nexans ref. 10170097 - Country ref. 01101295

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 14.5 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 353 kg/km

 

TCX (I) 150/250V 10P0.75

Nexans ref. 10170099 - Country ref. 01101296

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 17.5 mm
  • Maximum outer diameter: 20.0 mm
  • Approximate weight: 473 kg/km

 

TCX (I) 150/250V 14P0.75

Nexans ref. 10170102 - Country ref. 01101297

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 19.5 mm
  • Maximum outer diameter: 22.0 mm
  • Approximate weight: 610 kg/km

 

TCX (I) 150/250V 19P0.75

Nexans ref. 10183965 - Country ref. 01272265

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 21.5 mm
  • Maximum outer diameter: 24.5 mm
  • Approximate weight: 768 kg/km

 

TCX (I) 150/250V 24P0.75

Nexans ref. 10259830

  • Packaging: Cut to length (m)
  • Number of pairs: 24
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 24.0 mm
  • Maximum outer diameter: 27.0 mm
  • Approximate weight: 926 kg/km

 

TCX (I) 150/250V 2T0.75

Nexans ref. 10073618

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 2
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 230 kg/km

 

TCX (I) 150/250V 4T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 4
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.0 mm
  • Maximum outer diameter: 15.0 mm
  • Approximate weight: 290 kg/km

 

TCX (I) 150/250V 2P1.5

Nexans ref. 10170127

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 12.5 mm
  • Maximum outer diameter: 14.5 mm
  • Approximate weight: 260 kg/km

 

Description

Description

Standards

  • International
    IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TCX® (I) 150/250 V armoured individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

 

Design

  1. Conductor:
    Stranded bare copper class 2
     
  2. Insulation:
    XLPE (cross-linked polyethylene)
     
  3. Individual screen:
    Alu/polyester tape with a tinned copper drain wire
     
  4. Assembling:
    Polyester tape
     
  5. Armour:
    Bare copper braid
     
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : grey 
     

Marking

NEXANS 279 TCX (I) Nber of pairs/triads & cross section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat. A WW YYYY *CE* Manufacturing n° + metric marking

 

Core identification

Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Insulation
XLPE (Cross-linked Polyethylene)
Individual screen
Tinned copper drain wire + aluminium/polyester tape
Inner covering
Polyester tape(s)
Armour type
Bare copper braid
Outer sheath
Polyolefin
Sheath colour
Grey

Usage characteristics

Usage characteristics

Fire retardant
IEC 60332-3-22
Flame retardant
IEC 60332-1
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close